Interferences of Clearances of Housing Bores and Outer Rings: J6, JS6, J7, JS7 -1
Part 1 | Part 2 | Part 3 | |
Units : µm
| Size Classification(mm) |
Δ dmp |
Interferences or Clearances for Each Fitting Class |
J6 |
JS6 |
J7 |
JS7 |
C |
I |
C |
I |
C |
I |
C |
I |
| over |
incl |
high |
low |
max |
max |
max |
max |
max |
max |
max |
max |
| 6 |
10 |
0 |
-8 |
13 |
4 |
12.5 |
4.5 |
16 |
7 |
15 |
7 |
| 10 |
18 |
0 |
-8 |
14 |
5 |
13.5 |
5.5 |
18 |
8 |
17 |
9 |
| 18 |
30 |
0 |
-9 |
17 |
5 |
15.5 |
6.5 |
21 |
9 |
19 |
10 |
| 30 |
50 |
0 |
-11 |
21 |
6 |
19 |
8 |
25 |
11 |
23 |
12 |
| 50 |
80 |
0 |
-13 |
26 |
6 |
22.5 |
9.5 |
31 |
12 |
28 |
15 |
| 80 |
120 |
0 |
-15 |
31 |
6 |
26 |
11 |
37 |
13 |
32 |
17 |
| 120 |
150 |
0 |
-18 |
36 |
7 |
30.5 |
12.5 |
44 |
14 |
38 |
20 |
| 150 |
180 |
0 |
-25 |
43 |
7 |
37.5 |
12.5 |
51 |
14 |
45 |
20 |
| 180 |
250 |
0 |
-30 |
52 |
7 |
44.5 |
14.5 |
60 |
16 |
53 |
23 |
| 250 |
315 |
0 |
-35 |
60 |
7 |
51 |
16 |
71 |
16 |
61 |
26 |
| 315 |
400 |
0 |
-40 |
69 |
7 |
58 |
18 |
79 |
18 |
68 |
28 |
| 400 |
500 |
0 |
-45 |
78 |
7 |
65 |
20 |
88 |
20 |
76 |
31 |
| 500 |
630 |
0 |
-50 |
- |
- |
72 |
22 |
- |
- |
85 |
35 |
| 630 |
800 |
0 |
-75 |
- |
- |
100 |
25 |
- |
- |
115 |
40 |
| 800 |
1000 |
0 |
-100 |
- |
- |
128 |
28 |
- |
- |
145 |
45 |
|
|
|